The Apera Instruments DO850 oxygen meter is equipped with a state-of-the-art optical sensor for dissolved oxygen measurements. The optical sensor has no membrane and requires no special solutions. You will get a stable reading in 1 to 3 minutes. The sensor has a lifetime of up to 8000 hours of operation. The special coating on the cap protects the sensor from external influences and enables measurements independent of available light and chemicals. The meter is waterproof and dustproof (IP57 protection rating), allowing it to work in harsh environments.
Technical Specifications:
Technical Specifications:
| Dissolved oxygen (DO) | Measuring range | 0 to 200 %; 0-20.0 mg/l |
| Resolution | 0.1 / 1 %; 0.01 / 0.1 mg/l (ppm) | |
| Accuracy | ±2% of the display or ±2% of the saturation; ±2 % of the display or ±0.2 mg/l (ppm), the larger value counts in each case | |
| Response time | 90 % in ≤30 s (at 25 ℃ ) | |
| Calibration points | Saturation point & zero point | |
| Temperature compensation | 0 to 50 ℃ (automatic) | |
| Air pressure compensation | 60 to 120 kPa (automatic) | |
| Salt content compensation | 0-45 ppt (manual) | |
| Temperature | Measuring range | 0 to 50 °C |
| Resolution | 0,1 °C | |
| Accuracy | ±0.5 °C | |
| more | Power supply | 3 x AA batteries |
| Housing protection class | IP57 | |
| Size | 88×170×33 mm (with case 360×270×76 mm) | |
| Weight | 313 (with case 1,3kg) | |
| Certification | RoHs, CE & ISO9001:2015 |
A complete set contains:
- DO850 Meter
- DO803 Optical electrode for dissolved oxygen
- Electrode calibration cap
- Small screwdriver
- Sponge as water reservoir (replacement)
- operation manual
- Carrying case
| Descrizione | Valore |
|---|---|
| Parametri misurabili: | Sensori di ossigeno |
| Parametri misurabili: | Sensori di temperatura |
| Tipo di protezione IP: | IP57 |
| Tensione di alimentazione: | Battery |
| Strumento mobile: | sì |
| Descrizione | Valore |
|---|---|
| WEEE obligation: | sì |
| WEEE registration number: | DE 28154958 |
| WEEE brand according to EAR register: | APERA Instruments (Europe) GmbH |
| WEEE type of equipment: | Small equipment, that can be used in private households |